IAS-AF1800-MF Active Metal Foam
Air Filtration Unit
Technical Data Sheet — Revision 1.0 · Effective Date: November 2026 · Specifications to US practice (CFM, inches, in. w.g., °F, 120 V / 60 Hz)
airflow
(180 Pa)
at 1–3 µm
wash & reuse
electrical
Active Filtration,
Permanent Media
IAS-AF1800-MF is a fan-powered (active) air filtration unit built around a two-stage train of open-cell metal foam media — the full-size unit for intakes, make-up air and large-space recirculation. A variable-speed EC fan draws air through the foam train; captured dust loads through the depth of the foam instead of caking on a disposable face, and when the differential-pressure reading says so, the cassettes come out, are rinsed or pressure-washed in about five minutes per stage, and go back in with performance restored. It is a commercial air filter with no consumables at all: there is no disposable filter element anywhere in the unit, and upkeep is a simple wash.
The unit is built in two regional configurations on the same cabinet. IAS-AF1800-MF-DS (Desert Specification) pairs a coarse 10 PPI nickel-iron foam first stage — the sand and dust load stage — with a 30 PPI nickel-iron main stage, for the high-dust air of the US Southwest. IAS-AF1800-MF-HS (Humidity Specification) uses corrosion-resistant nickel foam (20 PPI + 40 PPI) in a 304 stainless steel housing with a condensate drain, for continuous duty in hot, humid, coastal air. Media cassettes are sized to the US-standard 24 × 24 in filter envelope, and connections, electrical supply and ratings all follow US practice, so the units interface with standard American ductwork, filter banks and building power.
Media figures are the published values for this metal foam family: 92.4% fractional efficiency at 1–3 µm, 96.8% at 3–10 µm, 85–95% open-cell porosity. OEM and private-label builds — your branding, voltage, housing material and colour — are supplied under our OEM program with the CUSTOM model suffix.

Complete Technical Specification
| Parameter | IAS-AF1800-MF |
|---|---|
| Nominal airflow | 1,800 CFM (3,060 m³/h), variable speed |
| Fan | EC backward-curved centrifugal, 0–10 V / dial speed control |
| Power draw (max) | 520 W |
| Electrical (US standard) | 120 V / 60 Hz standard; 208–230 V / 60 Hz option |
| Sound level | ≤62 dB(A) at 1 m, full speed |
| Media — DS configuration | Stage 1: nickel-iron foam, 10 PPI × 1 in (25 mm) · Stage 2: nickel-iron foam, 30 PPI × 1 in (25 mm) |
| Media — HS configuration | Stage 1: nickel foam, 20 PPI × 1 in (25 mm) · Stage 2: nickel foam, 40 PPI × 1 in (25 mm) |
| Media format | two 24 × 24 in media cassettes per stage; US-standard 24 × 24 in envelope |
| Media porosity | 85–95% open cell |
| Fractional efficiency (media) | 92.4% at 1–3 µm · 96.8% at 3–10 µm |
| Clean pressure drop, two-stage train | ≤0.72 in. w.g. (180 Pa) at nominal airflow |
| Housing | DS: powder-coated galvanized steel · HS: 304 stainless steel |
| Overall dimensions (W × D × H) | 48 × 24 × 36 in (1,219 × 610 × 914 mm) |
| Weight | DS 168 lb (76 kg) · HS 181 lb (82 kg) |
| Air connections | 16 in round duct collar or 48 × 24 in flange |
| Operating range | −4 to 122 °F (−20 to 50 °C) ambient · HS: up to 95% RH continuous, condensate drain fitted |
| Monitoring | Differential-pressure gauge ports across the media train; wash at ≈2× clean ΔP |
| List price | USD 9,900 per unit (DS and HS configurations); volume and OEM / private-label pricing on request |
| Consumables | None — the metal foam media is simply washed and reused; there are no replacement elements to buy |
| Maintenance | Wash media in place or removed, ≈5 min per stage; no disposable media; media design life 10+ years |
| Ozone generation | None — purely mechanical filtration (no ionization, plasma or UV) |
Applications
- DS (desert): data center, warehouse and manufacturing intake and make-up air in Arizona, Nevada and the US Southwest; evaporative-cooler and rooftop-unit intake protection; sites hit by haboob dust storms (PM10 spikes of 1,000–5,000 µg/m³)
- HS (humidity): hotels, coastal commercial buildings, food and beverage plants, gyms and warehouses in Florida and the Gulf Coast, where paper media absorbs moisture, sags and supports mould
- Stand-alone recirculation cleaning for large commercial and light-industrial spaces
- High-capacity prefiltration ahead of HEPA or gas-phase stages, extending final-filter life
Questions about IAS-AF1800-MF
Does IAS-AF1800-MF replace a HEPA filter?
No — it is a high-capacity particulate stage for dust and PM loads, sized to protect downstream equipment and to handle dust events that blind disposable media. Where HEPA or gas-phase removal is required, IAS-AF1800-MF stages ahead of it; see our data center and nuclear filtration lines.
What happens in a dust storm (DS configuration)?
The coarse nickel-iron first stage takes the sand load through its depth rather than on a face, so pressure drop rises gradually instead of spiking. After the event, wash the cassettes — about five minutes per stage — and the unit is back at its clean pressure drop, with no media to order or replace.
Why metal foam for Florida humidity (HS configuration)?
Nickel foam does not absorb water, does not sag, and gives mould nothing organic to grow on; it is corrosion-resistant, including in coastal salt air. The stainless housing and condensate drain are specified for continuous duty at up to 95% RH.
Can I order IAS-AF1800-MF under my own brand?
Yes — OEM and private-label supply, including branding, electrical configuration and housing options, runs under our OEM custom manufacturing program. Custom builds carry the CUSTOM suffix.