⭐ Featured
Nuclear
Sizing Guide
ACH targets by work type (4–15+ ACH), CFM formula, 6 worked examples (hot cell to 7,200 ft³), IAS-NC700-HI vs NC500 selection, multi-zone coverage, ALARA NRC compliance. Interactive calculator.
CFM sizingACHnuclear air cartALARA
⭐ Featured
Nuclear
Decommissioning
NRC 10 CFR 50 Subpart D, ALARA, 12 radiological contaminants (Cs-137, Co-60, alpha emitters), DECON vs SAFSTOR, portable cart sizing, IAS-NC700-HI and NC500 field deployment.
decommissioningDECONSAFSTORD&D
⭐ Featured
Nuclear
Maintenance Guide
HEPA replace at ΔP ≥1.0 in.WG or >0.03% in-place test. Carbon: >0.175% CH₃I or 5-year limit or >80°C. 6-step change-out procedure, printable maintenance log, Google Scholar references.
HEPA replacementcarbon change-outNRC RG 1.52TEDA
Nuclear
Testing Methods
Why DOP (IARC 2B carcinogen) was replaced by PAO (Emery 3004). Test methodology, ≤0.03% penetration acceptance, photometer vs OPC, 7-step procedure, NRC RG 1.52 annual requirements.
DOP PAOHEPA in-place testANSI N510photometer
Nuclear
Radiation Physics
Physical t½=8.02 days, effective 7.28 days, λ=0.08664/day. Decay table 0–80 days, DAC 2×10⁻⁸ µCi/mL, thyroid dose 5.1×10⁻⁸ Sv/Bq, NRC 10 CFR 35.75. Interactive decay calculator.
I-131 half-life8.02 daysDACthyroid dose
Nuclear
Carbon Testing
DIN 3754 cyclohexane (non-radioactive, 20°C/50% RH) vs ANSI N509/N510 methyl iodide (30°C/70% RH). NRC regulatory status, TEDA SN2 mechanism, acceptance criteria ≤0.175% CH₃I.
cyclohexanemethyl iodideDIN 3754ANSI N509
Nuclear
Product TDS
Full TDS: viscosity 1,300–1,400 cP, coverage 0.6–2.5 m²/L, film ≤2 hrs, peel ≤8 hrs, tensile ≥2.0 MPa ASTM D412. 6-step application, vs chemical spray/water jet comparison. ALARA benefit.
SDC-50strippable coatingdecontaminationALARA
⭐ Featured
Hospital
Standards Comparison
Side-by-side: ASHRAE 170 = mechanical ACH by room type (OR 20 ACH, ICU 6 ACH, AII 12 ACH negative). ASHRAE 241 = total ECA including air cleaning. Both apply simultaneously. Room table, decision tool.
ASHRAE 241 vs 170hospital HVACECA vs ACHIRMM
Hospital
ASHRAE 241
ASHRAE 241-2023 ECA formula, IRMM requirements (5 ACH min), surgical suites (15–20 ACH), ICU (7–10 ACH), isolation rooms (12 ACH). ECA calculation worked example. Technology comparison.
ASHRAE 241ECAIRMMhospital air cleaning
Hospital
Nuclear Medicine
NRC 10 CFR 35.75, negative pressure ≥0.01 in.WG, 6–12 ACH, HEPA + TEDA carbon filtration. Three-stage filter train, monitoring, case study: 750-bed medical center. ASHRAE 241 ECA contribution.
I-131therapy roomNRC 10 CFR 35.75negative pressure
Laboratory
Lab Systems
Dual-chamber 304 SS iodine absorption: 24-in × 36-in chambers, TEDA or silver silicate media, NOx removal >95%, GC-MS/FTIR sampling ports, variable flow kinetics, research configurations.
laboratorydual-chamberiodine absorptionGC-MS