IAS-DC-RIGID-2424 Rigid Box
Final Filter, MERV 13/14
Technical Data Sheet — Revision 1.0 · Effective Date: November 2026
capacity
(MERV 13 / 14)
media area
inches
Rigid Box
Final Filter
IAS-DC-RIGID-2424 is a rigid box final filter for data center air handling units and filter-wall banks, built around the MERV 13/14 range that ASHRAE Technical Committee 9.9's own guidance names as the preferred filtration for air entering a data center. It is normally installed downstream of a MERV 8 pleated prefilter such as IAS-DC-PANEL-2424.
The media is wet-laid microfine glass fiber held apart by safe-edge aluminum separators for uniform airflow and full media utilization, sealed into a galvanized-steel frame with an aluminized finish for corrosion resistance. The 24 × 24 × 12 in. envelope is rated for 2,000 cfm at both MERV grades.
Built to the same published dimensional and performance specification as Camfil Aeropac (24 × 24 × 12 in., MERV 13/14). Camfil and Aeropac belong to Camfil; Iodine Air Systems is not affiliated with Camfil. Confirm interchangeability against your housing before ordering.
Media & Frame
Product photography for IAS-DC-RIGID-2424 is in preparation. Construction and dimensional detail are fully specified in the table below.
- Wet-laid, microfine glass-fiber media
- Safe-edge aluminum media separators
- Galvanized-steel enclosing frame with aluminized finish for added corrosion resistance

Complete Technical Specifications
| Parameter | MERV 13 | MERV 14 |
|---|---|---|
| — Dimensions — | ||
| Nominal size | 24 × 24 × 12 in. (610 × 610 × 305 mm) | |
| Actual size | 23.31 × 23.31 × 11.31 in. | |
| — Performance — | ||
| Airflow capacity | 2,000 cfm (≈3,400 m³/h) | 2,000 cfm (≈3,400 m³/h) |
| Initial resistance | 0.60 in. w.g. (≈150 Pa) | 0.65 in. w.g. (≈162 Pa) |
| Recommended final resistance | 1.5 in. w.g. (≈374 Pa) | |
| Media area | 105 sq ft | |
| Efficiency rating | MERV 13 or MERV 14 per ASHRAE 52.2-2012 with Appendix J (MERV-A); ISO 16890 | |
| — Media & construction — | ||
| Media | Wet-laid, microfine glass fiber | |
| Separators | Safe-edge aluminum | |
| Frame | Galvanized steel, aluminized finish | |
| — Listing & limits — | ||
| Listing | UL Class 900 | |
| Max. operating temperature | 200 °F (90 °C) | |
Metric values are conversions of the US customary specification. Specification values are those published for the Camfil Aeropac reference product (see cross-reference above); Iodine Air Systems' own factory test reports are confirmed at quotation.
Applications
- Final-filter stage in data center air handling units, downstream of a MERV 8 prefilter
- Filter-wall bank final filtration
- Sites targeting ASHRAE TC9.9's ISO 14644-1 Class 8 room cleanliness guidance
- Retrofits into existing side-access rigid-box filter housings
For a prefilter stage upstream, see IAS-DC-PANEL-2424. For a higher-media-area V-bank alternative in the same envelope, see IAS-DC-VBANK-2424.
Questions about IAS-DC-RIGID-2424
Is IAS-DC-RIGID-2424 a replacement for Camfil Aeropac?
It is built to the same published dimensional and performance specification as Camfil Aeropac in 24 × 24 × 12 in.: 2,000 cfm airflow capacity, 0.60 in. w.g. (MERV 13) / 0.65 in. w.g. (MERV 14) initial resistance, and 105 sq ft of media. It is an Iodine Air Systems product, not a Camfil product, and we are not affiliated with Camfil. Confirm interchangeability against your housing before ordering.
Should I choose MERV 13 or MERV 14?
ASHRAE Technical Committee 9.9's own guidance names MERV 11 or preferably MERV 13 for air entering a data center. MERV 14 gives a finer cut at a higher initial resistance (0.65 in. w.g. vs. 0.60 in. w.g. at the same 2,000 cfm) and is chosen where a site's own specification, economizer use, or local air quality calls for it.
What is the difference between this and the V-bank filter, IAS-DC-VBANK-2424?
Both share the 24 × 24 × 12 in. envelope and the 2,000 cfm rating, but this rigid box construction carries 105 sq ft of media, built to the Camfil Aeropac reference specification; the V-bank reference products in the IAS-DC-VBANK-2424 line carry different media areas depending on grade and manufacturer. Construction style (rigid box vs. V-bank) and initial resistance differ — see each product's own specification table.
What does the recommended final resistance mean?
1.5 in. w.g. is the manufacturer-published recommended changeout point for this filter family. Your building management system or a manometer on the filter bank tracks differential pressure against that figure; system design may dictate a different changeout point for your installation.
How do I order?
Email sales@iodineairsystems.com with the part number (MERV grade), quantity, delivery destination, Incoterm (FOB or CIF), and your required date. Pricing and lead time are confirmed in the quotation.