IAS-TW10 Tritium Surface Contamination Wipe Monitor — No P-10 Gas

A portable counter for tritium wipe (smear) samples that needs no P-10 counting gas. Wipe a 100 cm² area, place the wipe in the instrument and read the removable tritium contamination in under 2 minutes.

Surface contamination / wipe monitor Portable, no P-10 gas Calibration certificate + CoC Updated September 2026

Quick answer

IAS-TW10 is a surface contamination / wipe monitor in the IAS-T tritium monitoring series from Iodine Air Systems. It counts 100 cm² tritium wipe samples in under 2 minutes without P-10 gas. Portable; calibration certificate and certificate of conformance included; price on quotation.

Illustration of the IAS-TW10 Tritium Surface Contamination (Wipe) MonitorwipeIAS-TW10
Illustration only, not a product photograph. Photos and drawings supplied with the quotation.
< 2 minResponse time
100 cm²Measurement area (= 1 dm²)
No P-10Counting gas needed
< 2.7 kg6.0 lb, portable

What the IAS-TW10 does

Tritium surface contamination cannot be found with a standard frisker, because tritium beta particles (maximum 18.6 keV) do not get through a detector window. The usual method is a wipe (smear) counted by liquid scintillation, which means cocktail, vials, a lab counter and a wait.

The IAS-TW10 gives a field result in under 2 minutes and does not use P-10 counting gas, so there are no gas bottles to carry or change. It measures a 100 cm² wipe, which is the same area as the US dpm/100 cm² convention. Readings are shown in kDPM/dm² (1 kDPM/dm² = 1,000 dpm/100 cm²), nCi/dm² or Bq/cm², with an alarm level that can be set anywhere in the range.

Know its resolution: stated accuracy is ±4.44 kDPM/dm² (±4,440 dpm/100 cm²) from 0 to 100 kDPM/dm², and ±10% above that. DOE's removable-contamination value for tritium in 10 CFR 835 Appendix D is 10,000 dpm/100 cm². Many NRC and Agreement State licensees use 1,000 dpm/100 cm² removable limits, which is below the IAS-TW10's low-level accuracy. The IAS-TW10 is therefore a fast screening and triage tool for higher-level contamination. For release decisions and routine low-level surveys, use liquid scintillation counting. Wet wipes are often preferred for tritium, since 10 CFR 835 notes that dry material may not be appropriate.

Key features

IAS-TW10 specifications

Measured sampleWipe (smear) samples from surfaces
Measurement range0 – 1 Ci/dm²
Measurement area100 cm² (1 dm²)
Response time< 2 min
Accuracy±4.44 kDPM/dm² (0–100 kDPM/dm²); ±10% (> 100 kDPM/dm²)
Display unitskDPM/dm² (= 1,000 dpm/100 cm²), nCi/dm², Bq/cm²
AlarmSettable over the full range
Display / controlLCD touchscreen
Counting gasNone (no P-10)
Operating environment15–50 °C (59–122 °F); 5–65% RH
Dimensions150 × 178 × 254 mm (5.9 × 7.0 × 10.0 in)
Weight< 2.7 kg (6.0 lb)
PowerStated on quotation

Specifications are nominal manufacturer values and may change. Confirmed values are stated on the quotation and data sheet. DAC multiples use the tritiated-water DAC of 2 × 10⁻⁵ µCi/mL (7.4 × 10⁵ Bq/m³) from 10 CFR 20 Appendix B and 10 CFR 835 Appendix A.

Typical applications

US supply, documentation and quality

Iodine Air Systems supplies the IAS-T series as an authorized distributor. Instruments are built by our manufacturing partner to our US configuration. Each quotation states the exact deliverables, lead time and country of origin.

Compare with related IAS-T models

See the full IAS-T tritium monitor range or use the tritium DAC converter to check a reading against your limits.

IAS-TW10 FAQ

Can a normal frisker detect tritium contamination?

No. Tritium betas have a maximum energy of 18.6 keV and cannot penetrate a typical detector window, so surface tritium is measured by wiping the surface and counting the wipe, either with liquid scintillation or a wipe monitor such as the IAS-TW10.

Does the IAS-TW10 need P-10 gas?

No. It does not use P-10 counting gas, so there are no gas cylinders to manage.

Can the IAS-TW10 replace liquid scintillation counting?

No. Use it for fast screening of higher-level contamination. Its stated accuracy at low levels is ±4,440 dpm/100 cm², so it cannot resolve common 1,000 dpm/100 cm² limits, and results near the DOE value of 10,000 dpm/100 cm² should be confirmed by liquid scintillation counting.

What units does it report?

kDPM/dm², nCi/dm² and Bq/cm². Because its measurement area is 100 cm² (1 dm²), 1 kDPM/dm² equals 1,000 dpm/100 cm².

How much does the IAS-TW10 cost?

The IAS-TW10 is priced on quotation. The price depends on options, quantity, power version, documentation package and delivery destination. Send the quote form on this page or email sales@iodineairsystems.com, and we reply with price, lead time and the list of documents supplied.

Is the IAS-TW10 available for US 120 V power?

Yes. Mains-powered IAS-T models are available in a 120 V AC / 60 Hz US version, and in 220–230 V / 50 Hz for export.

What documents come with the IAS-TW10?

A factory calibration certificate, a certificate of conformance, product certification documents and an English operating manual. A commercial-grade dedication support package is available for purchasers who dedicate the instrument for safety-related use.

Request a quote: IAS-TW10

Fill in what you know and press Email or WhatsApp. Your message is prepared for you to send. Nothing is stored on this page.

Or call +1 (307) 533-0268 · sales@iodineairsystems.com