Chat on WhatsApp
+1 (307) 533-0268
IAS-T Series · IAS-TG10

IAS-TG10 Wall-Mount Process Tritium Detector — 1 L, > 5 atm Rated

A compact, wall-mounted tritium detector with its own electrometer and signal processing. One network-type cable carries both communication and power. Any PLC or RS-485 master can read it, so you can put the detector at the glovebox instead of running long sample lines to a rack.

Process detector (wall-mount, PLC-ready) 120 V / 60 Hz US version Calibration certificate + CoC Updated September 2026

Quick answer

IAS-TG10 is a process detector (wall-mount, plc-ready) in the IAS-T tritium monitoring series from Iodine Air Systems. It measures tritium from 3.7 × 10⁴ to 3.7 × 10¹¹ Bq/m³ (1 µCi/m³ to 10 Ci/m³). US 120 V / 60 Hz version; calibration certificate and certificate of conformance included; price on quotation.

Illustration of the IAS-TG10 Wall-Mount Process Tritium Detectordata + powerIAS-TG10
Illustration only, not a product photograph. Photos and drawings supplied with the quotation.
> 5 atmChamber pressure rating
1 LAll-metal wire-wall chamber
≤ 1×10⁻⁹Pa·m³/s leak rate
1 cableCommunication and power

What the IAS-TG10 does

The IAS-TG10 puts the detector where the tritium is. Its 1 L wire-wall chamber is laser-welded and metal-sealed, has ceramic-brazed feedthroughs and contains no organics. It is rated above 5 atm, with a leak rate of ≤ 1 × 10⁻⁹ Pa·m³/s, which suits gloveboxes and process systems with strict leak-tightness requirements.

Because the electrometer and signal processing are built into the detector, the output is a digital Modbus value rather than a femtoamp current on a long cable. One network-type cable carries communication and power, so integration into a PLC, DCS or glovebox controller is simple.

Key features

IAS-TG10 specifications

DetectorWire-wall ionization chamber, 1 L effective volume (gold-plated option)
Range (SI)3.7 × 10⁴ to 3.7 × 10¹¹ Bq/m³
Range (US units)1 µCi/m³ to 10 Ci/m³ (10⁻⁶ to 10 µCi/mL)
Range as HTO DAC multiples0.05 DAC to 500,000 DAC (HTO DAC 2E-5 µCi/mL)
Pressure rating> 5 atm (> 500 kPa)
Leak rate≤ 1 × 10⁻⁹ Pa·m³/s (≈ 1 × 10⁻⁸ mbar·L/s)
ConstructionLaser-welded chamber and tubing, metal seals; ceramic-brazed feedthrough; no organic materials in chamber
Sample flow1–9 L/min
Gas connectionsVCR or compression fittings
Operating environment−10 to 85 °C (14–185 °F); 0–95% RH
CommunicationEthernet or RS-485; Modbus/TCP or Modbus
Detector sizeØ 300 × 150 mm (Ø 11.8 × 5.9 in)
With wall bracket150 W × 180 D × 400 H mm (5.9 × 7.1 × 15.7 in)
MountingWall-mount
Power120 V AC / 60 Hz (US version); 220–230 V / 50 Hz export version supply; < 100 W

Specifications are nominal manufacturer values and may change. Confirmed values are stated on the quotation and data sheet. DAC multiples use the tritiated-water DAC of 2 × 10⁻⁵ µCi/mL (7.4 × 10⁵ Bq/m³) from 10 CFR 20 Appendix B and 10 CFR 835 Appendix A.

Typical applications

US supply, documentation and quality

Iodine Air Systems supplies the IAS-T series as an authorized distributor. Instruments are built by our manufacturing partner to our US configuration. Each quotation states the exact deliverables, lead time and country of origin.

Compare with related IAS-T models

See the full IAS-T tritium monitor range or use the tritium DAC converter to check a reading against your limits.

IAS-TG10 FAQ

Does the IAS-TG10 need a separate readout unit?

No. The electrometer and signal processing are inside the detector. Any PLC or host with Modbus over RS-485 or Ethernet can read it directly.

What pressure can the IAS-TG10 chamber withstand?

The chamber is rated above 5 atm (more than 500 kPa) and has a leak rate of 1 × 10⁻⁹ Pa·m³/s or less.

Can several IAS-TG10 detectors be networked?

Yes. Each detector is a Modbus device, so several gloveboxes or process points can report to one PLC or SCADA system.

How much does the IAS-TG10 cost?

The IAS-TG10 is priced on quotation. The price depends on options, quantity, power version, documentation package and delivery destination. Send the quote form on this page or email sales@iodineairsystems.com, and we reply with price, lead time and the list of documents supplied.

Is the IAS-TG10 available for US 120 V power?

Yes. Mains-powered IAS-T models are available in a 120 V AC / 60 Hz US version, and in 220–230 V / 50 Hz for export.

What documents come with the IAS-TG10?

A factory calibration certificate, a certificate of conformance, product certification documents and an English operating manual. A commercial-grade dedication support package is available for purchasers who dedicate the instrument for safety-related use.

Request a quote: IAS-TG10

Fill in what you know and press Email or WhatsApp. Your message is prepared for you to send. Nothing is stored on this page.

Or call +1 (307) 533-0268 · sales@iodineairsystems.com

Related pages

Sources